The Two-Pressure Circuit: High Side vs Working Side

learnfrc.com
learnfrc.comAuthor
Veer Bajaj
Veer BajajMaintainer

The FIRST Pneumatics Manual describes the system as a high-pressure side (up to 120 psi) and a working-pressure side (60 psi or less) , divided by the primary regulator. Air is generated and stored at high pressure for capacity, then stepped down to a gentler working pressure that valves and cylinders actually use. Keeping these straight is the single most important concept in this department.

Everything from the compressor up to the inlet of the primary regulator. By rule (R809 in the 2026 manual) the permitted components here are tightly limited:

  • Compressor — squeezes air into the system.
  • Pressure relief valve — a mechanical safety that vents if pressure exceeds the limit; it must be connected directly to the compressor with hard fittings and is set to release at 125 psi.
  • Air storage tank(s) — hold compressed air for the match.
  • Pressure switch / transducer — tells the controller when to run or stop the compressor.
  • Stored-pressure gauge — shows storage pressure.
  • Vent plug (vent valve) — a hand-operated valve to dump all stored air safely.
  • Primary regulator — the boundary device that steps high-side storage down to working pressure.

The rules also allow filters and additional pressure sensors/transducers on this side. Solenoid valves and cylinders are not permitted upstream of the regulator.

Downstream of the primary regulator, where the action happens. It is more flexible and typically includes:

  • Solenoid valves — electrically switch air to move cylinders (single or double).
  • Pneumatic actuators — air cylinders or rotary actuators that produce motion.
  • Manifolds (optional) — blocks that feed many valves from one supply to reduce plumbing.
  • Flow-control / needle valves (optional) — slow a cylinder’s motion.
  • Additional regulators (optional) — further reduce pressure for a specific actuator.
  • Working-pressure gauge — shows regulated pressure.

Storing at up to 120 psi packs more usable air into your tanks (more actuations per charge), while running cylinders at a capped 60 psi keeps forces predictable and components within their ratings. The regulator is the translator between the two worlds. Internalize this diagram now: as you wire, program, and pass inspection, you will constantly ask ‘which side of the regulator is this part on?’

  • The circuit has a high-pressure storage side (up to 120 psi) and a working side (60 psi max) separated by the primary regulator.
  • By R809 the high side allows only compressor, relief valve, tank(s), pressure switch/transducer, gauge, vent plug, regulator, filters, tubing, and fittings.
  • The working side holds solenoid valves, cylinders, optional manifolds, flow controls, and extra regulators.
  • Storing high and working low maximizes air capacity while keeping cylinder forces safe and predictable.