When something doesn’t work, trace the power and signal path methodically from the battery outward. Most faults fall into a few categories.

A brownout happens when battery voltage sags too low under heavy load and the roboRIO protectively cuts power to outputs to avoid rebooting. At Stage 1 , when the bus drops below about 6.8V , the 6V output on the PWM pins begins to drop (the 5V and 3.3V user rails are not disabled yet). The full output-disable brownout (Stage 2) is what shuts down the 6V/5V/3.3V user rails and the motor outputs, and its threshold depends on the version: the roboRIO 1.0 is fixed at 6.3V , while the roboRIO 2.0 defaults to 6.75V and is software-adjustable. Below ~4.5V the device blacks out entirely (Stage 3).

Causes and fixes:

  • Tired battery - check internal resistance; retire anything over ~0.020 ohms.
  • Too many motors stalling at once - add software current limiting on CAN controllers.
  • High-resistance connections - a loose lug or cold crimp drops voltage; re-crimp and tighten.
  • Use the PDH voltage display or the Driver Station log to watch voltage while driving.
  • A breaker that keeps tripping signals a mechanism jam, a stalled motor, or an undersized breaker for the load - investigate the mechanism first.
  • A blown fuse (roboRIO/radio) means a short or overload on that 10A circuit - find the short before replacing.
  • A device disappears - check its connectors and crimps; CAN is a chain, so a break kills everything downstream of it.
  • Erratic behavior - look for duplicate CAN IDs.
  • Flaky comms - verify termination (~60 ohms) and that CANH/CANL aren’t swapped.
  • Use Phoenix Tuner X (CTR) or the REV Hardware Client (REV) to see which devices are present.
  • Radio LEDs - confirm the VH-109 is powered and linked.
  • roboRIO LEDs - green Power and a healthy Status LED.
  • Check the Ethernet link between roboRIO and radio.
  • Confirm the Driver Station shows communication and robot code green.
  • Multimeter - check voltage and continuity, measure CAN termination resistance.
  • Battery tester (Battery Beak) - resting voltage and internal resistance.
  • Driver Station Log Viewer - voltage, brownout events, and current over a match.
  • PD telemetry / PDH LED display - spot the channel drawing too much.
  1. Reproduce the fault.
  2. Check the simplest causes first (battery, main breaker, loose connectors).
  3. Use telemetry to localize the bad channel or device.
  4. Fix one thing, re-test, and confirm before moving on.
  • Brownouts come from sagging voltage under load - the roboRIO sheds load near 6.8V; full brownout is 6.3V (RIO 1.0) or a 6.75V default (RIO 2.0, adjustable).
  • Fix brownouts with healthy batteries, tight low-resistance connections, and software current limiting.
  • A repeatedly tripping breaker usually means a jammed mechanism or stalled motor, not just an undersized breaker.
  • CAN faults trace to loose connectors, duplicate IDs, or missing termination - diagnose with Phoenix Tuner X / REV Hardware Client, a multimeter, and the Driver Station Log Viewer.