The power distribution device (PD) takes the single 12V feed from the main breaker and splits it into many branch circuits , each protected by its own breaker. It is the central junction box of the robot. For 2026 the legal PDs are the CTRE PDP and PDP 2.0 , the REV PDH , and AndyMark Power Distribution (added to R609 in 2026). The two you will see most are the PDP and the PDH.

Made by CTR Electronics , the original PDP has:

  • 8 channels rated 40A continuous and 8 channels rated 30A continuous (16 channels, numbered 0-15).
  • Dedicated terminals for the roboRIO and for the VRM/PCM/radio.
  • A CAN interface that logs total current, per-channel current (in 0.125A increments), bus voltage (in 0.05V increments), temperature, power, and energy.
  • Uses Snap-Action automotive blade breakers and ATM fuses.

There is also a PDP 2.0 with more 40A-capable channels that accepts ATC/ATO fuses but lacks the original PDP’s built-in per-channel current logging.

Made by REV Robotics (P/N REV-11-1850), the PDH has:

  • 20 high-current channels (40A max) , 3 low-current channels (15A continuous, 20A peak) , and 1 switchable low-current channel (24 channels total, numbered 0-23).
  • Toolless WAGO lever terminals - no screwdriver needed, just lift the lever and insert the wire.
  • An LED input-voltage display showing battery voltage at a glance.
  • CAN and USB-C connectivity; USB-C works with the REV Hardware Client for live telemetry, firmware updates, and as a USB-to-CAN bridge.
  • High-current channels accept ATO-size breakers/fuses; low-current channels accept ATM/APM breakers/fuses.
  • The switchable channel can be turned on or off in code with setSwitchableChannel(true).
  • CTREPDP defaults to CAN ID 0.
  • REV PDH defaults to CAN ID 1.

WPILib’s PowerDistribution class auto-detects the module type; created with no arguments it expects CAN ID 0 for CTRE or 1 for REV.

Both are excellent. The PDH’s toolless terminals and onboard voltage display speed up assembly and pit debugging; the original PDP’s per-channel current logging is invaluable for diagnosing brownouts. Many teams pick based on what’s in their Kit of Parts.

  • The PDP has 16 channels (eight 40A + eight 30A) with per-channel current logging; default CAN ID 0.
  • The PDH has 24 channels (20 high-current 40A, 3 low-current 15A, 1 switchable) with toolless WAGO terminals; default CAN ID 1.
  • For 2026, AndyMark Power Distribution joins the PDP/PDP 2.0 and PDH as a legal PD.
  • WPILib’s PowerDistribution class auto-detects the module and reports current (0.125A on PDP), voltage, power, and energy over CAN.